Jdsolar 2kw off Grid Solar Power Supply System with Solar Panel Controller Inverter Cable
Jdsolar 2kw off Grid Solar Power Supply System with Solar Panel Controller Inverter Cable
Produktbeschreibung
Solar Power System Product Manual
Product title: JDSOLAR Solar Power System
Product alias: JDSOLAR photovoltaic power generation system
Product model: SOLAR SYSTEM
Use range of JDSOLAR solar power generation system
Suitable for various outdoor places. It can meet the lighting needs of home users such as villas, peasant rooms, homes, sun rooms, and homestays.
Performance characteristics of JDSOLAR solar power system
Lighting performance: can meet daily household use, stable performance
Working time: When using a generator to generate electricity, during the day
Convenient: automatic operation, no need to watch
JDSOLAR Solar Power Generation System
Thank you for choosing our solar products. This product is strictly controlled in accordance with the ISO9001 national quality system standards. The photovoltaic module is guaranteed for 10 years, the inverter is guaranteed for 5 years, the battery is guaranteed for 1 year, and the system is guaranteed for 2 years. Within two years from the date of purchase, non-artificial damage to the product will be repaired by the company for free.
JDSOLAR photovoltaic module main technical indicators
I. Photovoltaic module photoelectric conversion efficiency
(I) Definition of photoelectric conversion efficiency
Photovoltaic module photoelectric conversion efficiency refers to the ratio of the maximum output power of a photovoltaic module to the solar power of the module under standard test conditions (AM1.5, module temperature of 25 ° C, and irradiance of 1000W / m2).
(2) Determination of photoelectric conversion efficiency
The photovoltaic module's photoelectric conversion efficiency is tested by a third-party testing laboratory that has passed the National Qualification Accreditation (CMA) in accordance with the method specified in the GB / T 6495.1 standard. If necessary, the temperature and irradiance can be corrected according to the GB / T 6495.4 standard.
The calculation formula is:
(Where the module area is the entire area of the photovoltaic module including the frame)
Mass production of photovoltaic modules must be certified by a certification body approved by the State Accreditation Administration, and the deviation between the actual power and the nominal power of each individual module product must not be higher than 2%. The corresponding peak power technical indicators of the photoelectric conversion efficiency of several commonly used standard crystalline silicon modules are as follows:
Material Type Cell
Size (mm) Cell
Quantity 15.5% conversion efficiency corresponds to module peak power (Wp) 16% conversion efficiency corresponds to module peak power (Wp) 16.5% conversion efficiency corresponds to module peak power (Wp) 17% conversion efficiency corresponds to module peak power (Wp)
Polysilicon 156 * 156 60 255/270 /
156 * 156 72 305/325 /
Monocrystalline silicon 156 * 156 60/260/275
156 * 156 72/315/330
For non-standard crystalline silicon photovoltaic modules (such as dual-glass modules), the conversion efficiency may not be calculated according to the above formula, but the efficiency of the cells used should be consistent with the requirements for the photoelectric conversion efficiency of the cells in the Ministry of Industry and Information Technology's "Standard Conditions for Photovoltaic Manufacturing Industry" And must be certified by a certification body approved by the State Accreditation Administration.
For concentrating photovoltaic modules, the standard test conditions are AM1.5, the module temperature is 25 ° C, the irradiance is 1000W / m2, and the module area is the corresponding lens area.
Second, the attenuation rate of photovoltaic modules
(I) Definition of photovoltaic module attenuation rate
Photovoltaic module attenuation rate refers to the ratio of the maximum output power under standard test conditions (AM1.5, module temperature 25 ° C, irradiance 1000W / m2) to the initial maximum output power after commissioning after a period of operation.
(2) Determination of the attenuation rate of photovoltaic modules
The determination of the attenuation rate of photovoltaic modules can adopt accelerated aging test methods, field comparison verification methods or other effective methods. The accelerated aging test method is to use an environmental test box to simulate the environmental conditions such as irradiance, temperature, and humidity during actual outdoor operation, and to double or tighten related parameters to achieve the purpose of accelerating the aging and attenuation of components in a short time. . After the accelerated aging test is completed, a power test is performed on the test module under standard test conditions, and the attenuation rate of the photovoltaic module's power generation performance is determined according to the attenuation rate formula.
The field comparison method is to take a sufficient number of component samples according to the installed capacity of the project from the date of component production and operation. After the initial maximum output power, it is installed in the same environment as other components produced in the same batch to run normally to generate electricity, and its maximum output power is measured again one year after the date of operation. The maximum output power before and after the comparison is compared, and the attenuation rate of the photovoltaic module's power generation performance is determined according to the calculation formula of the attenuation rate.
The calculation formula is:
Product title: JDSOLAR Solar Power System
Product alias: JDSOLAR photovoltaic power generation system
Product model: SOLAR SYSTEM
Use range of JDSOLAR solar power generation system
Suitable for various outdoor places. It can meet the lighting needs of home users such as villas, peasant rooms, homes, sun rooms, and homestays.
Performance characteristics of JDSOLAR solar power system
Lighting performance: can meet daily household use, stable performance
Working time: When using a generator to generate electricity, during the day
Convenient: automatic operation, no need to watch
JDSOLAR Solar Power Generation System
Thank you for choosing our solar products. This product is strictly controlled in accordance with the ISO9001 national quality system standards. The photovoltaic module is guaranteed for 10 years, the inverter is guaranteed for 5 years, the battery is guaranteed for 1 year, and the system is guaranteed for 2 years. Within two years from the date of purchase, non-artificial damage to the product will be repaired by the company for free.
JDSOLAR photovoltaic module main technical indicators
I. Photovoltaic module photoelectric conversion efficiency
(I) Definition of photoelectric conversion efficiency
Photovoltaic module photoelectric conversion efficiency refers to the ratio of the maximum output power of a photovoltaic module to the solar power of the module under standard test conditions (AM1.5, module temperature of 25 ° C, and irradiance of 1000W / m2).
(2) Determination of photoelectric conversion efficiency
The photovoltaic module's photoelectric conversion efficiency is tested by a third-party testing laboratory that has passed the National Qualification Accreditation (CMA) in accordance with the method specified in the GB / T 6495.1 standard. If necessary, the temperature and irradiance can be corrected according to the GB / T 6495.4 standard.
The calculation formula is:
(Where the module area is the entire area of the photovoltaic module including the frame)
Mass production of photovoltaic modules must be certified by a certification body approved by the State Accreditation Administration, and the deviation between the actual power and the nominal power of each individual module product must not be higher than 2%. The corresponding peak power technical indicators of the photoelectric conversion efficiency of several commonly used standard crystalline silicon modules are as follows:
Material Type Cell
Size (mm) Cell
Quantity 15.5% conversion efficiency corresponds to module peak power (Wp) 16% conversion efficiency corresponds to module peak power (Wp) 16.5% conversion efficiency corresponds to module peak power (Wp) 17% conversion efficiency corresponds to module peak power (Wp)
Polysilicon 156 * 156 60 255/270 /
156 * 156 72 305/325 /
Monocrystalline silicon 156 * 156 60/260/275
156 * 156 72/315/330
For non-standard crystalline silicon photovoltaic modules (such as dual-glass modules), the conversion efficiency may not be calculated according to the above formula, but the efficiency of the cells used should be consistent with the requirements for the photoelectric conversion efficiency of the cells in the Ministry of Industry and Information Technology's "Standard Conditions for Photovoltaic Manufacturing Industry" And must be certified by a certification body approved by the State Accreditation Administration.
For concentrating photovoltaic modules, the standard test conditions are AM1.5, the module temperature is 25 ° C, the irradiance is 1000W / m2, and the module area is the corresponding lens area.
Second, the attenuation rate of photovoltaic modules
(I) Definition of photovoltaic module attenuation rate
Photovoltaic module attenuation rate refers to the ratio of the maximum output power under standard test conditions (AM1.5, module temperature 25 ° C, irradiance 1000W / m2) to the initial maximum output power after commissioning after a period of operation.
(2) Determination of the attenuation rate of photovoltaic modules
The determination of the attenuation rate of photovoltaic modules can adopt accelerated aging test methods, field comparison verification methods or other effective methods. The accelerated aging test method is to use an environmental test box to simulate the environmental conditions such as irradiance, temperature, and humidity during actual outdoor operation, and to double or tighten related parameters to achieve the purpose of accelerating the aging and attenuation of components in a short time. . After the accelerated aging test is completed, a power test is performed on the test module under standard test conditions, and the attenuation rate of the photovoltaic module's power generation performance is determined according to the attenuation rate formula.
The field comparison method is to take a sufficient number of component samples according to the installed capacity of the project from the date of component production and operation. After the initial maximum output power, it is installed in the same environment as other components produced in the same batch to run normally to generate electricity, and its maximum output power is measured again one year after the date of operation. The maximum output power before and after the comparison is compared, and the attenuation rate of the photovoltaic module's power generation performance is determined according to the calculation formula of the attenuation rate.
The calculation formula is:
Lieferfähigkeit
Verpackung und Versand
- Vorlaufzeit:
- Hafen:
- Verpackungsdetails:
>=1 Set(s)
US 1500.00-2000.00
Kommentare
Willkommen bei unzuun Kommentaren! Bitte halten Sie die Gespräche höflich und thematisch. Um produktive und respektvolle Gespräche zu fördern,
Sie können Kommentare von unseren Community Managern sehen.
Melden Sie sich an, um zu posten
Melden Sie sich an, um weitere Kommentare anzuzeigen
Diese Inserate könnten Sie auchinteressieren.
Meo Machinery Co.LTD
Portable Mini Complete Kit 3kw 3kva 3000W Solar Power Panel off Grid Systems for Home
Meo Machinery Co.LTD
20kw Home Solar System Price 20kw 10kw Grid Tie Home Energy System
Meo Machinery Co.LTD
Pure Sine Wave Power Off grid solar hree-phase Inverter Price
Meo Machinery Co.LTD
solar inverter 3KVA 2400W 24V to 220V 230V built-in PWM 50A
Meo Machinery Co.LTD
4KW Single Phase 220v Home Use Dual MPPT Grid Tied Ssolar Power Inverter /DC AC Inverter with APP Remote Monitoring
Meo Machinery Co.LTD
KWSKJ 3KVA 2400Winverter pure sine wave 2020 power inverter air conditiones 30a 12v 24v LCD MPPT solar controller
Meo Machinery Co.LTD
Factory wholesale customization smart voltage control solar controller inverter
Meo Machinery Co.LTD
TOP price portable Solar Machine power Panel Solar Pannels 1000w System Roof Generator Home 3kw 5kw Complete Energy X84
Meo Machinery Co.LTD
High Efficiency Solar Inverter Off Grid 3KW 24V 220V 380V 660V
Meo Machinery Co.LTD
Efficient off-grid home mini solar home system inverter system
Meo Machinery Co.LTD
TOP Sale INVT AC/DC BN 6kW Off-grid Inverter AC/DC cheap price
Meo Machinery Co.LTD